X1-HAC-4 / X1-HAC-7 / X3-HAC-11 / X3-HAC-22
4kW/7kW/11kW/22kW
Freely adjustable power in the range of 1.4 to 22 kW
Green/Eco/Fast charging modes adjustable
Dynamic loads balance
Smart control and monitoring via SolaX APP
Support maximun 60 units in parallel with datahub, ease meets C&I needs
Scheduling charging to lower household electricity costs
Integrate with third-party platform
Support OCPP, Modbus TCP/RTU, Open API protocols
SolaX Cloud API Accessible to EMS
Wi-Fi, LAN and 4G multiple networking solutions supported
Support voice control
Easy installation
RFID/NFC/APP authentication modes supported
IP65 and IK10
Experience a revolutionary charging journey with the SolaX Smart EV Charger G2, perfectly tailored to complement your electric vehicle. Capable of utilizing 100% green energy generated from your solar or wind generation, the SolaX Smart EV Charger G2 is designed to maximize efficiency and sustainability. With its advanced Smart Energy System, you'll enjoy fast and reliable charging capabilities, whether you prefer a specific plug or socket. Optimize your charging schedule and minimize costs with intelligent load balancing and customizable timers.
Catalog | Specification | X1-HAC-4 |
AC Nominal Input | Voltage [V] | 230 |
Frequency [Hz] | 50/60 | |
Grid Earth Type | TN, TT, IT | |
AC Nominal Output | Voltage [V] | 230 |
Current [A] | 6-20 (single phase) | |
Power [kW] | 1.4-4.6 | |
Interface & Communication | Communication interface | Wifi/Ethernet/4G (Optional)/RS 485*2 |
Protocol | OCPP 1.6j, Modbus TCP, Modbus RTU, Cloud API | |
Communicate | IEC 61851-1, ISO 15118 (Optional) | |
Authentication | Plug&Charge/RFID (ISO-14443-A)/APP | |
MID meter | External(Optional) | |
HMI | RGB LED / APP / LCD(Optional) | |
Remote control | APP&Web | |
Application | Residential/Destination place/Public | |
General Data | Housing material | PC |
Installation method | Wall/Pedestal(Optional) | |
Charging outlet | Type2 Plug/Type2 Socket (IEC 62196) | |
Cable length(m) | 6.5(Type P) | |
Operating Temperature(°C) | -30~50 | |
Storage Temperature(°C) | -40~60 | |
Working humidity(%) | 5%~95% without condensation | |
Working altitude(m) | 2000 | |
Degree of Protection | IP65 (For plug type)/IP54 (For socket type) | |
Cooling method | Nature cooling | |
Application site | Indoor/Outdoor | |
Weight [kg] | 5 for Plug Type | |
Dimension(WxHxD) [mm] | 390x206x139 | |
Security Protection | Multiple Protection | Over/Under voltage protection,Overload protection,Shortcircuit protection, Current leakage protection,Grounding protection,Surge protection, Overtemperature protection |
Integral Earth Leakage Protection | Integrated current failure monitoring (30mA AC & 6mA DC) | |
Cable protection | Cable Lock (APP control) | |
Relay protection | Relay weld detection | |
Built-in PEN fault technology | According to BS 7671:2018 requirements* | |
Standard | IEC 61851-1:2017, IEC 62196-2:2016 |
Catalog | Specification | X1-HAC-7 |
AC Nominal Input | Voltage [V] | 230 |
Frequency [Hz] | 50/60 | |
Grid Earth Type | TN, TT, IT | |
AC Nominal Output | Voltage [V] | 230 |
Current [A] | 6-32 (single phase) | |
Power [kW] | 1.4-7.2 | |
Interface & Communication | Communication interface | Wifi/Ethernet/4G (Optional)/RS 485*2 |
Protocol | OCPP 1.6j, Modbus TCP, Modbus RTU, Cloud API | |
Communicate | IEC 61851-1, ISO 15118 (Optional) | |
Authentication | Plug&Charge/RFID (ISO-14443-A)/APP | |
MID meter | External(Optional) | |
HMI | RGB LED / APP / LCD(Optional) | |
Remote control | APP&Web | |
Application | Residential/Destination place/Public | |
General Data | Housing material | PC |
Installation method | Wall/Pedestal(Optional) | |
Charging outlet | Type2 Plug/Type2 Socket (IEC 62196) | |
Cable length(m) | 6.5(Type P) | |
Operating Temperature(°C) | -30~50 | |
Storage Temperature(°C) | -40~60 | |
Working humidity(%) | 5%~95% without condensation | |
Working altitude(m) | 2000 | |
Degree of Protection | IP65 (For plug type)/IP54 (For socket type) | |
Cooling method | Nature cooling | |
Application site | Indoor/Outdoor | |
Weight [kg] | 3 for Socket Type 5 for Plug Type | |
Dimension(WxHxD) [mm] | 390x206x139 | |
Security Protection | Multiple Protection | Over/Under voltage protection,Overload protection,Shortcircuit protection, Current leakage protection,Grounding protection,Surge protection, Overtemperature protection |
Integral Earth Leakage Protection | Integrated current failure monitoring (30mA AC & 6mA DC) | |
Cable protection | Cable Lock (APP control) | |
Relay protection | Relay weld detection | |
Built-in PEN fault technology | According to BS 7671:2018 requirements* | |
Standard | IEC 61851-1:2017, IEC 62196-2:2016 |
Catalog | Specification | X3-HAC-11 |
AC Nominal Input | Voltage [V] | 400 |
Frequency [Hz] | 50/60 | |
Grid Earth Type | TN,TT,IT | |
AC Nominal Output | Voltage [V] | 400 |
Current [A] | 6-16 (single phase) | |
Power [kW] | 1.4-11 | |
Interface & Communication | Communication interface | Wifi/Ethernet/4G (Optional)/RS 485*2 |
Protocol | OCPP 1.6j, Modbus TCP, Modbus RTU, Cloud API | |
Communicate | IEC 61851-1, ISO 15118 (Optional) | |
Authentication | Plug&Charge/RFID (ISO-14443-A)/APP | |
MID meter | External(Optional) | |
HMI | RGB LED / APP / LCD(Optional) | |
Remote control | APP&Web | |
Application | Residential/Destination place/Public | |
General Data | Housing material | PC |
Installation method | Wall/Pedestal(Optional) | |
Charging outlet | Type2 Plug/Type2 Socket (IEC 62196) | |
Cable length(m) | 6.5(Type P) | |
Operating Temperature(°C) | -30~50 | |
Storage Temperature(°C) | -40~60 | |
Working humidity(%) | 5%~95% without condensation | |
Working altitude(m) | 2000 | |
Degree of Protection | IP65 (For plug type)/IP54 (For socket type) | |
Cooling method | Nature cooling | |
Application site | Indoor/Outdoor | |
Weight [kg] | 3 for Socket Type 6.5 for Plug Type | |
Dimension(WxHxD) [mm] | 390x206x139 | |
Security Protection | Multiple Protection | Over/Under voltage protection,Overload protection,Shortcircuit protection, Current leakage protection,Grounding protection,Surge protection, Overtemperature protection |
Integral Earth Leakage Protection | Integrated current failure monitoring (30mA AC & 6mA DC) | |
Cable protection | Cable Lock (APP control) | |
Relay protection | Relay weld detection | |
Built-in PEN fault technology | According to BS 7671:2018 requirements* | |
Standard | IEC 61851-1:2017, IEC 62196-2:2016 |
Catalog | Specification | X3-HAC-22 |
AC Nominal Input | Voltage [V] | 400 |
Frequency [Hz] | 50/60 | |
Grid Earth Type | TN,TT,IT | |
AC Nominal Output | Voltage [V] | 400 |
Current [A] | 6-32 (single phase) | |
Power [kW] | 1.4-22 | |
Interface & Communication | Communication interface | Wifi/Ethernet/4G (Optional)/RS 485*2 |
Protocol | OCPP 1.6j, Modbus TCP, Modbus RTU, Cloud API | |
Communicate | IEC 61851-1, ISO 15118 (Optional) | |
Authentication | Plug&Charge/RFID (ISO-14443-A)/APP | |
MID meter | External(Optional) | |
HMI | RGB LED / APP / LCD(Optional) | |
Remote control | APP&Web | |
Application | Residential/Destination place/Public | |
General Data | Housing material | PC |
Installation method | Wall/Pedestal(Optional) | |
Charging outlet | Type2 Plug/Type2 Socket (IEC 62196) | |
Cable length(m) | 6.5(Type P) | |
Operating Temperature(°C) | -30~50 | |
Storage Temperature(°C) | -40~60 | |
Working humidity(%) | 5%~95% without condensation | |
Working altitude(m) | 2000 | |
Degree of Protection | IP65 (For plug type)/IP54 (For socket type) | |
Cooling method | Nature cooling | |
Application site | Indoor/Outdoor | |
Weight [kg] | 3 for Socket Type 6.5 for Plug Typ | |
Dimension(WxHxD) [mm] | 390x206x139 | |
Security Protection | Multiple Protection | Over/Under voltage protection,Overload protection,Shortcircuit protection, Current leakage protection,Grounding protection,Surge protection, Overtemperature protection |
Integral Earth Leakage Protection | Integrated current failure monitoring (30mA AC & 6mA DC) | |
Cable protection | Cable Lock (APP control) | |
Relay protection | Relay weld detection | |
Built-in PEN fault technology | According to BS 7671:2018 requirements* | |
Standard | IEC 61851-1:2017, IEC 62196-2:2016 |